Benefits of the 150W Aluminum Switching Power Supply:
Versatility: With its multiple output options, the 150W Aluminum Switching Power Supply can be used in a wide range of applications, including industrial automation, telecommunications, LED lighting, and more.
Stable and Reliable Power: The switch power supply provides a stable and regulated power output, protecting connected devices from voltage fluctuations and ensuring their proper operation.
Safety Features: The 150W Aluminum Switching Power Supply incorporates safety features such as over-load, over-voltage, and short-circuit protection, safeguarding both the power supply and the connected devices from potential damage.
Feature
1. Protection: short-circuit, overload
2. 100% full-load aged
3. Withstand 300VAC surge input for 5 seconds
4. -20~+60℃Working temperature
5. 5G vibration tested
6. High efficiency, long life span, and high reliability
7. Applications: Industrial automation machinery、Industrial control system、Testing and measuring instruments、Household appliances、Led lighting appliances、Aging equipment、IT communication equipment
8. Warranty: 3 years
9. Certificate: CE RoHS
150W Aluminum Switching Power Supply Specifications
NAME: |
LED POWER SUPPLY, LED DRIVER, LED Switching power supply LED power adapter, Led strip power supply, LED SMPS, aluminum swithcing power supply |
||
Model No. | 150W | SW-150-12 | SW-150-24 |
Output | DC Voltage | 12V | 24V |
Current Range | 0~12.5A | 0~6.255A | |
Power | 150W led power supply | ||
Ripple And Noise | Max 240mVp-p | ||
Voltage ADJ.Range | 10~13V | 22~26V | |
Voltage Tolerance | ±5% | ||
Setup, Rise Time | 1500ms, 30ms / 230VAC | ||
Input | Voltage Range | 90~260VAC | |
Frequency Range | 50~60Hz | ||
Efficiency | >0.85 | ||
PF | 0.6 | ||
Current | 7A/110VAC, 4A/220VAC | ||
Surge Current | 40A/110VAC, 60A/220VAC | ||
Leakage Current | Max 3.5mA/240VAC | ||
Protection | Overload | Above 110%-150% of rated power | |
Shut-down output voltage, auto recovery after fault condition is removed | |||
Overvoltage | Above Max. Voltage (105% of rated voltage) | ||
Shut-down output voltage, auto recovery after fault condition is removed | |||
Over temperature | 90℃ ± 5℃(5~12V) 80℃ ± 5℃(24V) | ||
Shut-down output voltage, auto recovery after fault condition is removed | |||
Environment | Working Temp. & humidity | "-20°C~+60°C, 20%~90%RH | |
Storage Temp. & humidity | "-40°C~+85°C, 10%~95%RH | ||
Safety | Withstand Voltage | I/P-O/P: 1.5KVAC/1min; I/P-F/G: 1.5KVAC/1min; O/P-F/G: 0.5KVAC/1min; | |
Safety | GB4943 ;IEC60950-1; EN60950-1 | ||
EMC | EN55032:2015/AC:2016; EN61000-3-2:2014; EN61000-3-3:2013; EN55024:2010+A1:2015 | ||
LVD | EN60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 | ||
Other | Cooling | free air | |
Lifespan | 20000hrs | ||
Dimensions (L*W*H) | 199*98*42mm | ||
Weight | 0.48KG | ||
Note |
1. The above mentioned data were measured at 230VAC input and 25°C. 2. Dis-connect the AC input before checking any mal-phenomenons. 3. Make sure the INPUT&OUPUT were in right situation before connected to power supply. 4. Datasheet for reference only. We suggest you take sampling before mass orders. |