High quality 12W Constant Current DALI CCT Dimmable LED Driver is offered by China manufacturers STARWELL. Buy 12W Constant Current DALI CCT Dimmable LED Driver which is of high quality directly with low price.
The standard Dali signal is used to control the brightness and color temperature. One power supply only occupies one address. The raw materials used are first-line brands, and the imported chips are super high Deep dimming design, matching a variety of Dali intelligent dimming systems and KNX Protocol Intelligent Systems on the market Accurately control the color temperature and brightness, and the color temperature can be adjusted according to the lamp beads Silica gel is used to balance the use range of electronic heat conduction components.
12W Constant Current DALI CCT Dimmable LED Driver Features:
1. Dali standard interface and standard DT8 protocol conform to Dali 144 standards
2. Dali2 certification, Dali member
3. Digital control output is adopted, and there is no stroboscopic
4. AC input 200-250v range
5. Natural air cooling, moisture-proof, heat conduction, silica gel heat dissipation process
6. Deep dimming design
7. Multiple protection functions
8. Ultra small volume design
9. Crimping design, convenient and fast
10. 4 gear current selection
11. 5-year warranty
12. TUV CE SAA ENEC certificate
13. Size: 116*30*21mm
12W Constant Current DALI CCT Dimmable LED Driver Model list:
DALI DT8 CCT constant current dimming
Series | Dimimng | Model | Input | Power | PF | Output voltage | Output current |
PE-L12DCA 3-11.2W flicker free |
DALI DT8
|
PE-L12DCA4028 | AC200-250V | 11.2W | 0.88-0.96PF THD<10% | 25-40V | 200/230/250/280mA |
PE-L12DCA4018 | AC200-250V | 7.2W | 0.88-0.96PF THD<10% | 25-40V | 100/130/150/180mA | ||
PE-L20DCA 10-20W flicker free |
DALI DT8
|
PE-L20DCA4050 | AC200-250V | 20W | 0.88-0.96PF THD<10% | 25-40V | 350/400/450/500mA |
PE-L20DCA4040 | AC200-250V | 16W | 0.88-0.96PF THD<10% | 25-40V | 250/300/350/400mA | ||
PE-L30DCA 20-30W flicker free |
DALI DT8
|
PE-L30DCA42 | AC200-250V | 29.4W | 0.88-0.96PF THD<10% | 25-42V | 550/600/650/700mA |
PE-L40DCA 30-40W flicker free |
DALI DT8
|
PE-L40DCA42100 | AC200-250V | 42W | 0.88-0.96PF THD<10% | 25-42V | 850/900/950/1000mA |
PE-L40DCA4290 | AC200-250V | 37.8W | 0.88-0.96PF THD<10% | 25-42V | 750/800/850/900mA |
12W Constant Current DALI CCT Dimmable LED Driver Application:
1.Led two-color light source
2.Villa intelligent lighting
3.Wireless intelligent lighting system can be accessed
4.Museum lighting
5.High end commercial lighting
12W Constant Current DALI CCT Dimmable LED Driver Specification:
Model | PE-L12DCA4028 | PE-L12DCA4018 | |
OUTPUT | Output Voltage | 25-40Vdc | 25-40Vdc |
Max Output Voltage | 40Vdc | 40Vdc | |
Non-load Output Voltage | 51Vdc | 51Vdc | |
Output Current | 200/230/250/280mA | 100/130/150/180mA | |
Output Power | 5W~11.2W | 2.5W~7.2W | |
Strobe Level | No-flicker percent (IEEE 1789 = 0.378%) , flicker index (IEEE 1789 = 0.001 pst = 0.005, SVM = 0.004(the test data were obtained from the dark room surface light source test) | ||
Dimming Range | 0~100%,LEDstart at 0.03%possible. | ||
PWM Dimming Frequency | >3600Hz | ||
Current Accuracy | ±5% | ||
Power down mode | memory function when power down | ||
INPUT | Dimming Interface | DALI (IEC62386)Signal control current < 2mA | |
Input Voltage Range | 200-250Vac | ||
Frequency | 50/60Hz | ||
Input Current | <0.52A ac230v | ||
Power Factor | PF>0.96/230V ac(at full load) | ||
THD | 230Vac@THD <10% (at full load) | ||
Efficiency(typ.) | 84% | 80% | |
Inrush Current(typ.) | cold start20A@230Vac | ||
Anti Surge | L-N: 1.5kV | ||
Leakage Current | <0.25mA/230Vac | ||
Environment | Working Temperature | ta: 45°C tc: 80 °C | |
Working Humidity | 20 ~ 95%RH, non-condensing | ||
Storage Temp., Humidity | -40 ~ 80°C, 10~95%RH | ||
Temp.Coefficient | ±0.03%/°C(0-50)°C | ||
Vibration | 10~500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes. | ||
PROTECTION | Over-heat Protection | Intelligently adjusting or turning off the output current if the PCB temperature ≥110°C, , auto recovers. | |
Over Load Protection | Shut down the output when rated power≥102%, auto recovers. | ||
Short Circuit Protection | Shut down automatically if short circuit occurs, auto recovers. | ||
Non-load Protection | output Constant Voltage. | ||
SAFETY & EMC |
Withstand Voltage | I/P-O/P: 3750Vac | |
Isolation Resistance | I/P-O/P: 100MΩ/500VDC/25°C/70%RH | ||
Safety Standards | IEC/EN61347-1, IEC/EN61347-2-13 | ||
EMC Emission | EN55015, EN61000-3-2 Class C, IEC61000-3-3 | ||
EMC Immunity | EN61000-4-2,3,4,5,6,8,11, EN61547 | ||
Strobe Test Standard | IEEE 1789 | ||
OTHERS | Dimension | 116×30×21mm(L×W×H) | |
Packing | PE bag | ||
Weight(G.W.) | 75g±10g |
Dimensions:
Led current selection:
Wiring diagram:
The abnormal conditions and the corresponding treatment methods:
Digital Addressable lighting Interface (DALI)
DALI slave unit will send data only master unit requests, that is, adopt command answering mode
There are 64 slave units at most in the same DALI network, each unit has a separate address(short address), A salve unit can also be assigned to a certain group, and a slave unit can belong to different group, salve unit can exist up to 16 groups at the same time, each unit can set 16 scenarios.
The main features of the DALI protocol
1)Asynchronous serial communication.
2)1200 baud rate, using the Manchester encoding format.
3)Two lies differential signal.
4)The high level when differential voltage is larger than 9.5V.
5)The low level when differential voltage is less than 6.5V.
6)The master unit controls communication process.
7)One DALI bus can connect with 64 slave units.
8)Each slave unit can be individually addressed.
DALI Electrical Specification
Under the idle state, from machine unit method to control the bus:
1)High Output power at ordinary time, not to interference in the hold signal.
2)Output low electricity at ordinary time, directly to the DALI bus short circuit to each other.
3)DALI bus maximum current of 250mA
4)Not a two-way communication at the same time.
5)Transmission cable up to 300 meters, or pressure drop is no more than 2v